Power timer, Configuring ups battery low shutdown, Wake-on-lan – NETGEAR ReadyNAS 2100 User Manual

Page 92: Power timer -4, Configuring ups battery low shutdown -4, Wake-on-lan -4

Advertising
background image

ReadyNAS 2100 User Manual

5-4

Optimizing Performance and Maintaining the System

v1.1, June 2009

Power Timer

The ReadyNAS 2100 can be scheduled to power off and power back on (on certain models)
automatically (see

Figure 5-3

). Select the Enable power timer check box and enter the action and

time. (The Power ON option is available on the ReadyNAS 2100 NV through an add-on
package.)

1

The Power ON option does not appear if the ReadyNAS 2100 hardware does not

support this feature.

Configuring UPS Battery Low Shutdown

If this device is not connected to a UPS device, you may elect to enable a UPS connection to
another NAS device. Select the Enable monitoring of UPS physically attached to a remote
ReadyNAS
check box and enter the IP Address in the Remote IP field. NETGEAR recommends
that you enable this feature if you have enabled the Disk Spin-Down option.

If you use this option, the ReadyNAS is shut down automatically when a battery-low condition is
detected on a UPS connected to another ReadyNAS. This is useful when a UPS is shared by
multiple ReadyNAS units, even though only one ReadyNAS is monitoring the battery status.

As an option, the ReadyNAS can remotely monitor the UPS when connected to a PC running
Network UPS Tools (NUT). For more information about NUT, see

http://www.networkupstools.org.

Wake-On-LAN

You can power-on this device remotely by sending it a “WOL Magic Packet” if the WOL service
is enabled.

1. Please refer to the Release Notes for RAIDiator 4 on the NETGEAR Support site for more information.

Note: When the ReadyNAS 2100 is powered off, any file transfers and backup jobs are

interrupted, and backup jobs scheduled during the power off state do not run.

Note: The ReadyNAS 2100 supports Wake-On-LAN on the first Ethernet interface

(LAN 1) only.

Advertising