11 - changing the filter, — recommended spares – Nilfisk-Advance America IVT-1000CR User Manual

Page 39

Advertising
background image

39

- The Exhaust filter ULPA cannot be cleaned! This

will have to be disposed off in an impervious bag

in accordance with any current regulation for the

disposal of such waste.

o The mounting plate for the exhaust filter and the

top cover of the motor shall be wiped down with a

suitable detergent.

o The vacuum gauge has to dismounted from the

top container before cleaning

o Wipe down the vacuum gauge (manometer) with a

suitable detergent

o All NON cleanable parts such as

o Main filter (HEPA in the H-class appliance)

o Exhaust filter (ULPA)

o Dust handling media (dust bag in std. appliance

or ”Dust safe Bag” in the H-class appliance)

o Has to be disposed of in an impervious bag in

accordance with any current regulation for the

disposal of such waste.

11 - Changing the filter

11.1 — Changing the main filter

Attention!!

When the vacuum has been used on materials that are

hazardous to the operatorʼs health, maintenance staff

must wear suitable personal protection equipment.

When replacing the primary filter. Work outdoors

if possible. The old filter shall be disposed of in

impervious bags in accordance with any current

regulation for the disposal of such waste.

Loosen the clamp fixing the filter assembly on the

machine.

Remove the motorhead from the machine.

Detach the gasket securing the filter ring at the bottom

of the top container.

Unclip the filter in the top of the container and place the

filter in a plastic bag.

Follow the instructions given in the top of this

paragraph.

Close the plastic bag containing the filter.

If this is soiled with toxic or dangerous dust, do not

throw it away. Hand it over to the authorities that are

authorized to dispose of such waste.

Change the main filter and the “H” class filter with

particular care, above all use mask type P3.

Attention!!

Filter replacement is an important operation.

The filter must be replaced with one of identical

characteristics, exposed filtering area and category.

Failure to comply with these regulations could

jeopardize the correct operation of the appliance.

Fit the filter in the container as described above in

opposite order.

11.2 — Changing the exhaust filter (fig. 11)

Disconnect the vacuum cleaner from the power

supply before starting the work!

attention: Observe correct operator protection in

accordance to regulations against material kept in the

ULPA filter.

Removing the handle

Detach the handle by unscrewing the two screws.

Release the handle by a gentle downward pressure at

its centre.

Press and release the handle from the recesses.

Removing and replacing the filter cartridge and

gaskets

Unscrew the four screws.

Lift-away the stainless steel housing with filter

cartridge.

Replace the filter cartridge and gaskets.

Refit the filter housing by pressing on the top, to mount

the four screws.

Remount the handle and fix in position with the 2

screws.

The dismounted and replaced exhaust filter shall be

disposed of in impervious bags in accordance with any

current regulation for the disposal of such waste.

Execute the change of the exhaust filter with particular

care above all use the mask type P3.

Note

The exhaust filter is toxic waste and must be treated as

such.

Hand it over to one of the authorities authorized to

dispose of such materials.

11.3 – Annual inspection and maintenance.

- The manufacturer, or an instructed person,

shall perform a technical inspection at least

annually, consisting of inspection of filters for

damage, seals and gasket for ari teightness of

the appliance and proper function of the control

mechaninsm.

- On H-class appliances, the appliance filtration

efficiency should be tested at least annually, or

more frequently as may be specified by national

requirements. The test method that can be used

to verify the applianceʼs filter efficiency are

specified in IEC 60335-2-69 in AA.22.201.2 – if

the test fails, it shall be repeated with a new

essential filter.

- When carrying out inspections, service or repair

operations, all contaminated items, which cannot

be satisfactorily cleaned, are to be disposed of;

such items shall be disposed of in impervious

bags in

accordance with any current regulation

for the disposal of such waste.

12. — Recommended spares

The following is a list of spare parts that should be kept

ready at hand in order to speed up maintenance work.

Part no.:

Description:

81303215

HEALTH & SAFETYBAG 5 PCS

81620000

DUST BAG 6.5 L, 5 PCS

80556600

ULPA FILTER KIT

80353000

SEALING FOR INLET

61909800

GORE-TEX FILTER

80386700

SEALING FOR CONTAINER

32410000

HEPA FILTER KIT

21545700

10 M CORD 3X1.0 MM

Advertising