N-Tron 710FX2 User Manual

Page 10

Advertising
background image

(Revised 2012-05-01

Page 10 of 170

WARNING: Do not work on equipment or cables during periods of lightning activity.

WARNING: Do not perform any services on the unit unless qualified to do so.

WARNING: Do not block the air vents.

WARNING: Observe proper DC Voltage polarity when installing power input cables. Reversing voltage
polarity can cause permanent damage to the unit and void the warranty.

Hazardous Location Installation Requirements

1.

This equipment is suitable for use in Class I, Div. 2, Groups A, B, C, D or non-hazardous locations
only.


2.

WARNING: Explosion Hazard – Substitution of components may impair suitability for Div. 2.

3.

WARNING: Explosion Hazard - do not disconnect while circuit is live, unless area is known to be
non-hazardous.

4.

WARNING: Explosion Hazard – do not replace the device unless power has been switched off or
the area is known to be non-hazardous.

5.

Use 90°C or higher rated Copper wire, (0.22Nm) 2lb/in Tightening torque for field installed
conductors.

Please make sure the 710FX2 Series Ethernet Switch package contains the following items:

1.

710FX2 Series Switch

2.

Product CD


Contact your carrier if any items are damaged.

Installation

Read the following warning before beginning the installation:

WARNING

Never install or work on electrical equipment or cabling during periods of lightning activity. Never connect
or disconnect power when hazardous gasses are present.

Disconnect the power cable before removing any enclosure panel.

UNPACKING

Remove all the equipment from the packaging, and store the packaging in a safe place. File any damage
claims with the carrier.