Nortel Networks OPTera Metro 3500 User Manual

Page 121

Advertising
background image

Operation, administration, and maintenance (OAM) features 2-83

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Client Service Mismatch

This alarm is raised against the LAN port
of a 2xGigE/FC-P2P circuit pack when
one of the following conditions occurs:

• the client service provisioned on the

remote 2xGigE/FC-P2P circuit pack
does not match the client service
provisioned on the local
2xGigE/FC-P2P circuit pack.

• the Sub-rate and Extended reach

parameters for a Fibre Channel facility
are not provisioned to the same setting.

Critical, service affecting (C, SA)

Far End Client Rx Signal Fail

This alarm is raised against a
2xGigE/FC-P2P circuit pack when a
problem occurs at the far-end
2xGigE/FC-P2P circuit pack that
terminates the service.

Critical, service affecting (C, SA)

Note:

Refer to

Gigabit Ethernet Drop and Continue

feature description for more details on this alarm. If the alarm

is raised against the WAN port of 2xGigE/FC interface and no other WAN and/or SONET related alarms are active,
the following must be performed to clear the alarm:

— Delete all cross-connections to the WAN port
— Delete the Ethernet facility (DLT-ETH)
— Add the Ethernet facility (ENT-ETH)
— Re-enter the unidirectional cross-connection(s)

Refer to

Bandwidth Management,

323-1059-320,

Equipment and Facility Provisioning

, 323-1059-350 and Alarm

and Trouble Clearing, 323-1059-543.

Table 2-12 (continued)
Egress WAN port and service alarms

Alarm

Description

Severity

Advertising
This manual is related to the following products: