Wiring diagrams – Nordyne Forced Air Gas and Oil Furnace M1M User Manual

Page 34

Advertising
background image

34

20. WIRING DIAGRAMS

703887B

Figure 40. Gas Atmospheric Furnace, M1GH 056, 070 Models

Gas Atmospheric Furnaces, M1GH 056, 070

ON/OFF

SWITCH

GAS VALVE

FAN SWITCH

HI-LIMIT

AUX. LIMIT

TRANSFORMER

L1

N

C

R

24 V

115 V

WHITE

WHITE

WHITE

GRAY

BLUE

BLACK

GRAY

FAN ON/AUTO SWITCH

ORANGE

ORANGE

BLACK

L1

NEUTRAL

GROUND

SCREW

FURNACE ELECTRICAL BOX

BLACK

3A FUSE

BLOWER MOTOR HEATING

ONLY

6
5
4
3
2
1

C

R

W

GRAY

RED

BLUE

CONNECTOR

HOUSING CAP

COMMON

FOR OPTIONAL

ACCESSORY KITS

BLACK

BLACK

LEGENDS

115V:

F

IELD 115V:

24V:

F

IELD 24V:

RED

NOTES

1.

Incoming power must be polarized. Observe

color coding. (See furnace data label for

electrical information.)

2.

If any of the original wires (as supplied with

the appliance) must be replaced, use 105˚C

Thermoplastic type wire or its equivalent.

BLACK

BLACK

SUPPLIED

BY INSTALLER

BLUE

WHITE

MANUAL RESET

VENT SWITCH

Advertising