All weather roof jack assemblies, Figure 6. roof jack assemblies – Nordyne Forced Air Gas and Oil Furnace M1M User Manual

Page 7

Advertising
background image

7

ROOF JACK

SLANT DECK
FLASHING

PITCHED
ROOF

CEILING

CEILING CAVITY

ROOF OPENING

CEILING OPENING

"X" (SEE TABLE 6)

S O T 27 45 -5

S= SLAT FLASHING
F= FLAT FLASHING

O= TYPE; STANDARD
H= HIGH WIND
A= ARCTIC ROOF JACK

T= TRANSIT

MODE
TYPE

MIN. ADJ.
LENGTH

MAX. ADJ.LENGTH

5 = 5" FLUE DIA.

MODEL

APPROX. ADJ.

NUMBER

LENGTHS*

BELOW FLASHING

FO1323 -5

13" - 23"

FO2343 -5

23" - 43"

SO1835 -5

18" - 35"

SO2447 -5

24" - 47"

SO3263 -5

32" -63"

SO4895 -5

48" - 95"

SOT2442 -5

24" - 42"

SOT2745 -5

27" - 45"

SOT4581 -5

45" - 81"

FOT2846 -5

28" - 46"

Table 5. Roof Jack Assemblies

a. Regardless of the location, the return air

opening into the closet shall not be less than
specified in the appliance’s listing.

b. Means shall be provided to prevent inadvert-

ent closure by a flat object placed over the
return air opening when it is located in the floor
of the closet (versus the vertical front or side
wall).

c. The cross-sectional area of the return duct

system leading into the closet, when located
in the floor or ceiling shall not be less than 235
square inches (or 390 square inches for 5 ton
ready M1 Furnaces).

d. The total free area of openings in the floor or

ceiling registers serving the return air duct
system must be at least 235 sq. in. At least
one register should be located where it is not
likely to be covered by carpeting, boxes and
other objects.

e. Materials located in the return duct system

must have a flame spread classification of
200 or less. This includes a closet door if the
furnace is in a closet.

f. Noncombustible pans having 1" upturned

flanges are located beneath openings in a
floor duct system.

g. Wiring materials located in the return duct

system shall conform to Articles 300-22 of
the National Electrical Code (ANSI C1/NFPA-
70).

S

S

AW

T

27 47 - 2

AW= ALL WEATHER

FLASHING
PITCH/12" RISE
0=FLAT
2=2.5/12
4=4/12

MIN. ADJ.
LENGTH

F=
S=

FLAT FLASHING
SLANT FLASHING

TYPE:
BLANK=NON-TRANSIT
T= TRANSIT MODE

MAX. ADJ.
LENGTH

FLUE STEEL TYPE
A= ALUMINIZED
S=STAINLESS

All Weather Roof Jack Assemblies

Approx. Length

Model Number

Below Flashing

(F,S)AW(T)1523-(0,2,4)(A,S)

15" - 23"

(F,S)AW(T)2135-(0,2,4)(A,S)

21" - 35"

(F,S)AW(T)2747-(0,2,4)(A,S)

27" - 47"

(F,S)AW(T)3563-(0,2,4)(A,S)

35" - 63"

(F,S)AW(T)5195-(0,2,4)(A,S)

51" - 95"

Figure 6. Roof Jack Assemblies

ROOF JACK

SLANT DECK
FLASHING

PITCHED
ROOF

CEILING

CEILING
CAVITY

ROOF
OPENING

"X" (SEE TABLE 1)

Flue Pipe

Combustion

Air Pipe

56" or 76"

Furnace

"A"

"B"

Figure 7. Example of Flat Jack

with Flashing

Figure 8. Example of 2½/12 Slant Jack

with Flashing

5/12 ROOF SLOPE

2
SLANT DECK

/12

1 2

ROOF JACK WITH
2
FLASHING

/12 SLANT

1 2