23

HOOD SAFETY SWITCH OPERATION CHECK

While the engine is running, slightly open the hood (7) and
check that the engine stops immediately.
If the engine keeps running when the hood (7) is open,
contact an authorised Service Center or Retailer.

FUSE CHECK/REPLACEMENT/RESET

Drive the machine on a level ground and engage the
parking brake with the pedal (3) and the lever (4).
Turn the ignition key (82) to "0".
Open the hood (7).
Disconnect the battery negative connector (43).

Lamellar fuse check/replacement

Remove the fuse box cover (46).
Check/replace the relevant fuse among the following (Fig.
18):
F1: Main fuse (key circuit) (15 A)
F2: Filter shaker motor fuse (25 A)
F3: Manual vacuum system fuse (40 A) (optional)
F4: Vacuum system motor fuse (

30 A)

F5: Horn and fl ashing light fuse (10 A)
F6: Working light fuse (10 A) (optional)
Remove the electrical component box cover (50).
Check/replace the following fuse (Fig. 19):
FT: Drive system fuse (70 A)
Remove and check/replace the following fuse (63):
FR: Charging system fuse (70 A)

Circuit breaker check

Check for deactivation of one of the following fuses, then
reset it after the relevant motor has cooled down:
FA: Main broom motor circuit breaker (30 A) (47)
FB: Side broom motor circuit breaker (10 A) (48)

Assembly

Assemble the components in the reverse order of
disassembly.

1.

1.

2.
3.
4.

5.
6.

7.
8.

9.

10.

11.

F1

F2

F3

F6

F5

F4

S311406

Figure 18