Using rigid vent components, Fireplace vent connection – Napoleon Fireplaces PARK AVENUE GD82PT User Manual

Page 13

Advertising
background image

13

W415-0536 / B / 07.20.06

The vent system must be supported approximately every 3
feet for both vertical and horizontal runs. Use Wolf Steel vent
spacers or equivalent every 3 feet and either side of each
elbow to maintain the minimum 1¼” clearance between the
outer and inner vent pipes. Use Wolf Steel support ring as-
sembly or equivalent noncombustible strapping to maintain
the minimum clearance to combustibles for both vertical and
horizontal runs.

All inner exhaust and outer intake vent pipe joists

may be sealed using either Red RTV high temp
silicone sealant or Black high temp Mill Pac with
the exception of the fireplace exhaust flue collar
which must be sealed using Mill Pac (not supplied).

1. Move the fi re-
place into position.
Measure the vent
length required
between terminal
and fi replace tak-
ing into account
t h e a d d i t i o n a l
length needed for
the finished wall
surface and any
1¼” overlaps between venting components.

2. Apply high temperature sealant (W573-0007 not pro-

vided) to the outer edge of the 4” inner collar of the fi replace.
Attach the fi rst vent component and secure using 3 self
tapping screws. Repeat using 7” piping.

3. Holding the air terminal (with the air defl ectors to the

top and the lettering in an upright, readable position) insert
the terminal into both vent pipes with a twisting motion to
ensure that both the terminal sleeves engage into the vent
pipes and sealant. Secure the terminal to the exterior wall and
make weather tight by sealing with caulking (not supplied).

1. Install the 4” diameter aluminium fl exible liner to the

fi replace. Secure with 3 screws and fl at washers. Seal the
joint and screw holes using the high temperature sealant
(W573-0007 not provided).

2. Install the 7” diameter aluminium fl exible liner to the

fi replace. Attach and seal the joints.

FIREPLACE VENT CONNECTION

USING RIGID VENT COMPONENTS

HORIZONTAL AIR TERMINAL INSTALLATION

EXTENDED HORIZONTAL AIR TERMINAL

INSTALLATION

FIGURE 20

1. Follow the instructions

for “Horizontal Air Terminal
Installations”, items 1 to 3.

2. Continue adding com-

ponents alternating inner
and outer venting. Ensure
that all 4” venting and elbows
have suffi cient vent spacers
attached and each compo-
nent is securely fastened to
the one prior. Attach the 4”
telescopic sleeve to the vent
run.

Repeat using a 7” telescopic sleeve. Secure and seal as

before. To facilitate completion, attach 4” and 7” couplers to
the air terminal.

3. Install the air terminal. See item 3 of the Horizontal Air

Terminal Installation. Extend the 4” telescopic sleeve; con-
nect to the air terminal assembly. Fasten with self tapping
screws and seal. Repeat using the 7” telescopic sleeve.

HI-TEMP

SEALANT

7" PIPE

2" OVERLAP

4" PIPE

CAULKING

SCREWS

#10x2½"

CAULKING

SEALANT

HI-TEMP

FIGURE 21

VENTING

TELESCOPIC SLEEVE

20"
COUPLER

AIR TERMINAL

FIGURE 22