Napoleon Fireplaces PARK AVENUE GD82PT User Manual

Page 31

Advertising
background image

31

W415-0536 / B / 07.20.06

Remote wall switch
is in “OFF” position;
main burner comes
on when gas knob
is turned to “ON”
position.

Wall switch is mounted up-
side down

- reverse.

Faulty valve.

- replace.

- replace.

Remote wall switch is ground-
ing.

- check for ground (short); repair ground or replace wire.

Remote wall switch wire is
grounding.

Main burner goes
out; pilot goes out.

Refer to “MAIN BURNER GOES OUT; PILOT STAYS ON”

Vent is blocked

Vent is re-circulating

- check for vent blockage.

- check joint seals and installation.

4” fl exible vent has become
disconnected from fi replace.

- re-attach to fi replace.

Main burner goes
out; pilot stays on.

Pilot fl ame is not large enough
or not engulfi ng the thermo-
pile

- turn up pilot fl ame.
- replace pilot assembly.

Thermopile shorting

- clean thermopile connection to the valve. Reconnect.
- replace thermopile / valve.

Remote wall switch wire is too
long; too much resistance in
the system.

- shorten wire to correct length or wire gauge.

Faulty thermostat or switch.

- replace.

Pilot will not light.

- check if pilot can be lit by a match
- check that the wire is connected to the push button ignitor.
- check if the push button ignitor needs tightening.
- replace the wire if the wire insulation is broken or frayed.
- replace the electrode if the ceramic insulator is cracked or broken.
- replace the push button ignitor.

No spark at pilot burner

- fi ll the tank.

Out of propane gas

Spark gap is incorrect

- spark gap should be 0.150” to 0.175” (5/32” to 11/64” approx.) from
the electrode tip and the pilot burner. To ensure proper electrode loca-
tion, tighten securing nut (fi nger tight plus 1/4 turn).

No gas at the pilot burner

- check that the manual valve is turned on.
- check the pilot orifi ce for blockage.
- replace the valve.
- call the gas distributor.

Pilot goes out while
s t a n d i n g ; M a i n
burner is in ‘OFF’
position.

Gas piping is undersized.

- turn on all gas appliances and see if pilot fl ame fl utters, diminishes or
extinguishes, especially when main burner ignites. Monitor appliance
supply working pressure.
- check if supply piping size is to code. Correct all undersized piping.

Pilot burning; no
gas to main burner;
gas knob is on ‘HI’;
wall switch / ther-
mostat is on.

Themostat or switch is de-
fective.

- connect a jumper wire across the wall switch terminals; if main burner
lights, replace switch / thermostat.

Wall switch wiring is defec-
tive.

- disconnect switch wires &connect a jumper wire across terminals
1 & 3; if the main burner lights, check the wires for defects and / or
replace wires.

M a i n b u r n e r o r i f i c e i s - remove stoppage in orifi ce.

Faulty valve.

- replace.

SYMPTOM

PROBLEM

TEST SOLUTION

PILOT

BURNER

THERMOCOUPLE

THERMOPILE