pRoBleM:
1. Bad connections or wiring

If the connections or wiring are wrong, loose, shorted, or open, the system will
not operate properly. the symptoms could include: Blue Led flickers or is off,
intermittent operation or no operation.

solutions:

• Test your power supply connections
• Test your CAT-5 cable for shorts and opens

pRoBleM:
2. RF or electromagnetic interference

digital sources, poorly shielded sources, microwave ovens, cordless telephones,
cell phones, high definition television sets, light dimming controls and other
sources of electromagnetic fields can induce radio frequency noise and interfere
with your radio frequency gateway. the symptoms could include: Blue Led on RFG
continuously flickering or poor range, intermittent operation or no operation.

solutions:

• Move your RFG to a new mounting location
• Check to make sure the orientation of the external antenna is vertical
• Change the RF Channel the RFG is communicating on

note: theRe aRe ZIGbee “SnIFFInG” toolS avaIlable on the maRket that allow
an InStalleR to See RF Channel uSaGe by wI-FI anD otheR ZIGbee DevICeS