Nortel Networks CallPilot NN44200-700 User Manual

Page 43

Advertising
background image

1005r server

43

Internal LEDs

Description

Information

MPB96 board LEDs

The three red LEDs at the top of the MPB96 board are visible through
the grill at the back of the server.

The PCI FPGA Done LED (the closest to the card I/O bracket)
comes on at startup and turns off immediately. This indicates
that the board works properly and was detected correctly by the
system. If this LED stays on after the startup, the card is defective
and must be replaced.

The DSP FPGA Done LED comes on at startup and stays on
until the CallPilot drivers are loaded and the diagnostic screen
appears. If the LED stays on after the operating system starts and
the CallPilot diagnostic screen appears, then the MPB96 board is
defective or the DSP and NTBus drivers do not function properly.

The CTbus FPGA Done LED (the farthest from the card I/O
bracket) works in tandem with the DSP FPGA Done LED and
turns on and off at the same time.

POST beep codes

If an error occurs before video initialization, the POST emits beep codes
that indicate errors in hardware, software, or firmware.

A beep code is a series of separate tones, each equal in length. Record the
beep code sequence before calling Nortel technical support.

Beep count

Description

1, 2, or 3

A Memory error occurred. Reseat the memory or replace the DIMMs with
known good modules.

4 – 7 or 9 – 11

A fatal error occurred and indicates a possible serious system problem.
Remove all the add-in cards and restart the system. If the error still
occurs, contact Nortel support. If the beep codes are not generated after
you remove the add-in cards, insert the cards one at a time, booting the
system between each card addition, until the beeps again occur to reveal
the malfunctioning card.

8

A problem with the onboard video card occurred indicating a fault on the
server board.

BIOS error messages

When a recoverable error occurs during the POST, the BIOS displays an
error message describing the problem.

Nortel CallPilot

Troubleshooting Reference Guide

NN44200-700

01.05

Standard

5.0

26 June 2007

Copyright © 2007, Nortel Networks

.

Advertising