Caution – Renesas M3028BT-EPB User Manual

Page 10

Advertising
background image

M3028BT-EPB User’s Manual

Precautions for Safety

REJ10J1459-0200 Rev.2.00 Sep 16, 2006

CAUTION

Cautions to Be Taken for Turning On the Power:

z

Turn ON the power of the emulator and user system as simultaneously as possible. Turn OFF the power of the

emulator and user system as simultaneously as possible.


z

Do not leave either the emulator or user system powered on, because of leakage current the internal circuits may

be damaged.


z

When turning ON the power again after shutting OFF the power, wait about 10 seconds.

Cautions to Be Taken for Handling This Product:

z

Use caution when handling the main unit. Be careful not to apply a mechanical shock.


z

Do not touch the connector pins of the emulator main unit and the target MCU connector pins. Static electricity

may damage the internal circuits.


z

Do not pull this product by the communications interface cable or the cable for connecting to the emulator main

unit and emulation probe. The cable may cause a break.


z

Do not flex the flexible cable for connecting to the emulator main unit and emulation probe excessively. The

cable may cause a break.


z

Do not use inch-size screws for this equipment. The screws used in this equipment are all ISO (meter-size) type

screws. When replacing screws, use same type screws as equipped before.

Caution to Be Taken for System Malfunctions:

z

If the emulator malfunctions because of interference like external noise, do the following to remedy the trouble.

(1) Press the RESET switch on the PC7501’s front panel.
(2) If normal operation is not restored after step (1), shut OFF power to the emulator once and then reactivate it.

Caution to Be Taken for External Trigger Input Voltage:

z

Keep an external trigger input voltage of the emulator main unit less than a VCC voltage. Overvoltage may

cause damage to the internal circuits.


Page 8 of 86

Advertising