11.3 Remote Control Connection & Operation

Chapter 11

2.3

The

confi guration of the status code for both normal and alarm operations:

There are total 2 bytes of the status codes. Byte one, the fi rst 8 bits, shows the current status of the operation

modes that the unit is in. Byte two, the second 8 bits, shows the current status of the alarm operations of the

unit.

BYTE 1:

Status code for normal operation modes

Channel Select
1110 = CH1
1101 = CH2
1011 = CH3
0111 = CH4

Display Mode
0 = Quad screen display
1 = Full Screen display

Auto-sequencing mode
0 = Auto sequencing mode
1 = Quad or full screen mode

VCR mode
0 = VCR operation
1 = Live operation

Security Lock mode
0 = Security lock ON mode
1 = Security lock OFF mode

Menu Setup mode
00 = Menu setup mode

BYTE 1

BYTE 2

}

}

}

}

START

STOP

START

STOP

b7

b6

b5

b4

b3

b2

b1

b0

LOCK

VCR

SEQU

QUAD

CH4

CH3

CH2

CH1

P.34