BM40S

8. Maintenance

9. Storage

Before you remove cap, be sure there is no pressure in the
tank. in order to release pressure, invert unit upside down
and squeeze spray pistol (aim away from you). Pressure will
escape; when hissing stops, all pressure has been released.
Remove pump assembly by turning counter-clockwise. The
pump handle has two locking positions, one turning
clockwise and one counter-clockwise.

1. Remove cap and pour out remaining solution, then rinse all

parts thoroughly with clean water.

2. Add 1/2 gallon of fresh water in tank. Pressurize, and flush

pumping system by depressing trigger for at least two minutes;
then drain all remaining water.

• Periodically re-grease lid gasket as well as lid vent and pump

cylinder, where applicable.

• To ensure good performance, keep lid vent free of obstruction.

Before and after each use, make sure all connections are well
tightened. Service and replace worn parts as required.

Failure to follow manufacturer's recommendation of use and care
of unit will void any expressed or implied warranty. Do not use
chlorine or clorox. It will permanently damage pump system.

In the event that any part must be replaced or any maintenance or
repair work not described in this manual must be performed,
please contact a representative from the store nearest RedMax
authorized servicing dealer for assistance.

NOTE

NOTE

WARNING

SPRYAER MAINTENANCE TABLE

Dayly

System/Compornent

Procedure

or

Before Use

After Use

Lid Gasket

Grease

Lid Vent

Inspect/Clean

Pump

Grease

Connection

Inspect/Tight

Whole unit

Wash/inspect

Never store chemicals in your sprayer for any length of time

1. Before you remove cap, be sure there is no pressure in the

tank. in order to release pressure, invert unit upside down and
squeeze spray pistol (aim away from you). Pressure will
escape; when hissing stops, all pressure has been released.
Remove pump assembly by turning counter-clockwise. The
pump handle has two locking positions, one turning clockwise
and one counter-clockwise.

2. Remove cap and pour out remaining solution, then rinse all

parts thoroughly with clean water.

3. Add 1/2 gallon of fresh water in tank. Pressurize, and flush

pumping system by depressing trigger for at least two minutes;
then drain all remaining water.

4. Always store tank clean and empty in a dry, shaded location.