Recommended operating conditions, Electrical characteristics – Renesas HD74LVC1G66 User Manual

Page 3

Advertising
background image

HD74LVC1G66

Rev.3.00 Jul. 01, 2004 page 3 of 10

Recommended Operating Conditions

Item

Symbol

Min

Max

Unit

Conditions

Supply voltage range

V

CC

1.65

5.5

V

Control Input voltage range

V

I

0

5.5

V

Input/Output voltage range

V

I/O

0

V

CC

V

0

20

V

CC

= 1.65 to 1.95 V,

2.3 to 2.7 V

0

10

V

CC

= 3.0 to 3.6 V

Input transition rise or fall rate

∆t / ∆v

0

10

ns / V

V

CC

= 4.5 to 5.5 V

Operating free-air temperature

T

a

–40

85

°C

Note:

Unused or floating inputs must be held high or low.

Electrical Characteristics

Ta = –40 to 85°C

Item

Symbol

V

CC

(V)

Min

Typ

Max

Unit

Test condition

1.65 to 1.95

V

CC

×0.65 —

2.3 to 2.7

V

CC

×0.7

3.0 to 3.6

V

CC

×0.7

V

IH

4.5 to 5.5

V

CC

×0.7

1.65 to 1.95

V

CC

×0.35

2.3 to 2.7

V

CC

×0.3

3.0 to 3.6

V

CC

×0.3

Input voltage

V

IL

4.5 to 5.5

V

CC

×0.3

V

1.65

13

30

I

S

= 4 mA

2.3

9

20

I

S

= 8 mA

3.0

7.5

15

I

S

= 24 mA

On–state switch

resistance

R

ON

4.5

5.5

10

I

S

= 32 mA

V

I

=V

CC

or GND

1.65

74.5

120

I

S

= 4 mA

2.3

20

30

I

S

= 8 mA

3.0

11.5

20

I

S

= 24 mA

Peak on resistance

R

ON

(P)

4.5

7.5

15

I

S

= 32 mA

V

I

=V

CC

to GND

±1.0

Off-state switch

leakage current

I

S (OFF)

5.5

±0.1*

1

µA

V

I

= V

CC

and V

O

= GND or

V

I

= GND and V

O

= V

CC

,

V

C

= V

IL

±1.0

On-state switch

leakage current

I

S (ON)

5.5

±0.1*

1

µA

V

I

= V

CC

or GND, V

C

= V

IH

V

O

= Open

±1.0

Control input

current

I

IN

5.5

±0.1*

1

µA

V

IN

= V

CC

or GND

10

I

CC

5.5

1.0*

1

µA

V

IN

= V

CC

or GND

Quiescent

supply current

∆I

CC

5.5

500

µA

V

C

= V

CC

–0.6 V

Control input

capacitance

C

IC

5.0

3.0

pF

C

I/O(OFF)

5.0

6.0

Switch terminal

capacitance

C

I/O(ON)

5.0

13

pF

Note:

1. Ta = 25°C

Advertising