Raypak 400/401 User Manual

Page 5

Advertising
background image

5

7. Mount the Power Vent on the outer top.

8. Route the conduit harness of the Power Vent thru

the outer top hole, around the adapter towards the

back of the unit. Continue routing the harness thru the

corner slot, which leads to open area behind the

access panel. Finally, route only the wire harness thru

the 7/8” grommet hole located on the sway brace.

Follow instructions on page 7 to wire the Power Vent.

Note: Newer units have a 7/8” grommet located on the

rain shield, which would eliminate routing the harness

around the back corner.

9. Re-mount the jacket top to its original position and

screw in the four screws holding it down to the appli-

ance.

10. If the appliance is a 181, 182, 330 or 331, remove

the tabs underneath the power vent using a 5/16” nut

driver and relocate them closer to the center of the

Power Vent as shown in Fig. 1.

11. Mount the Power Vent assembly bottom on the 6”

vent as shown below. Twist the assembly downward.

Snap the mounting brackets into their appropriate slot

to hold the Power Vent in position. Note: While twisting

you may notice some roughness, this is due to a tight

seal between the 6” vent and the Power Vent flue box.

12. Re-mount the access panel.

13. Re-mount the front door along with the knurled

screw on the heater.

TABS

BEFORE

AFTER

Fig. 1: Reposition the Tabs as Necessary (see step 10)

Fig. 2: Draft Assembly

TOP VIEW

LEFT SIDE

FRONT VIEW

REAR VIEW

EXHAUST

OUTLET

Note: The 90° elbow may be used as a termination cap.

Advertising
This manual is related to the following products: