Dynamixel rx-28 – Robotis RX-28 User Manual

Page 31

Advertising
background image

DYNAMIXEL

RX-28

Status Packet Result NO

ERROR

Example 20

Lock all addresses except for Address 0x18 ~ Address0x23 for a Dynamixel

actuator with an ID of 0

Set Address 0x2F (Lock) to 1.



Instruction Packet

Instruction = WRITE_DATA, Address = 0x2F, DATA = 0x01



Communication

->[Dynamixel]:FF FF 00 04 03 2F 01 C8 (LEN:008)

<-[Dynamixel]:FF FF 00 02 00 FD (LEN:006)

Status Packet Result NO

ERROR

Once locked, the only way to unlock it is to remove the power.

If an attempt is made to access any locked data, an error is returned.

->[Dynamixel]:FF FF 00 05 03 30 40 00 87 (LEN:009)

<-[Dynamixel]:FF FF 00 02 08 F5 (LEN:006)

Range Error

Example 21

Set the minimum power (Punch) to 0x40 for a Dynamixel actuator with an ID of 0


Instruction Packet

Instruction = WRITE_DATA, Address = 0x30, DATA = 0x40, 0x00


Communication

->[Dynamixel]:FF FF 00 05 03 30 40 00 87 (LEN:009)

<-[Dynamixel]:FF FF 00 02 00 FD (LEN:006)

Status Packet Result NO

ERROR

30

Advertising