COMMON SUPPLY/RETURN
CONCENTRIC AIR DIFFUSER

SUPPLY AIR/PERFORMANCE

NOTE: The location of the combination supply and return diffuser should
not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM
[472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level
for units with CFM greater than 1000 [472 L/s]. If the diffuser is installed
with a greater distance than recommended above, the supply air may
become stratified above the required comfort area causing uncomforta-
ble conditions.

Accessory

Approximate CFM [L/s]-Supply Air

.12 [.030]

.07 [.017] .10 [.024]

Plenum & Supply/Return Duct

1575 [743] 1800 [850]

1300 [614]

.16 [.040]

.09 [.022] .13 [.032]

Diffuser

.11 [.027]

.06 [.015] .09 [.022]

Economizer

.17 [.042]

.24 [.060]

.17 [.042]

2200 [1038]

Diffuser Airflow CFM [L/s]

Range of Throw Ft. [m]

14 [4.27]-16 [4.88]

800 [378]-1200 [566]

18 [5.49]-28 [8.53]

1600 [755]-2000 [944]

ACCESSORY EQUIPMENT

Accessory

Description

Model

Application

Accessory

Model No.

Roofcurbs

RSNA-B

RXSG-AAA08 (8" [203 mm] Height)

RXSG-AAA14 (14" [356 mm] Height)
RXSG-AAA24 (24" [610 mm] Height)

Supply & Return Diffusers

RSNA-B

RXRN-BD15

Economizers (Downflow ONLY)

RSNA-B

RXRE-CAA30 (3 Position)

RXRD-CAM10 (Fully Modulating)

Fresh Air Damper

RSNA-B

RXRF-FAB1 (Motorized-35%)

RXRF-FAA1 (Fixed-35%)

Rectangular to Round Transition (Downflow)

RSNA-B

RXMC-CA02 (16" [406 mm] Ducts)
RXMC-CA03 (18" [457 mm] Ducts)

Filter Kit

RSNA-B

RXRY-B01

Low Ambient Control

RSNA-B

RXRZ-A18

High Pressure Control

RSNA-B

RXAB-A02

Sideflow Rectangular to Round Transition

RSNA-B

RXMC-BA01

Low Pressure Control

RSNA-B

RXAC-A02

LP Conversion Kits

RSNA-B

RXGJ-EP84W (White-Rodgers Gas Valve)

RXGJ-EP85H (Honeywell Gas Valve)

Canadian High Altitude Kit (for Natural Gas only*)

RSNA-B

RXRX-AH01

Designed to convert a side by side or an over and under arrange-
ment into a concentric distribution of air. The diffuser is flush
mounted, completely insulated, assembled, and internally baffled
to provide four way supply air distribution with a center return. To
make the assembly complete and ready to fit into a 2' [0.61 m] x
4' [1.22 m] suspended ceiling grid, the diffuser includes
adjustable supply louvers, hanging rings, anti-sweat gasket, and
round flanges for use with flexible ducts.

Model No.

RXRN-

Diameter

Inches [mm]

16 [406]

90 [40.82]

Shipping Wt.

Lbs. [kg]

Dimension A
Inches [mm]

20

1

/

2

[521]

BD15

SUPPLY/RETURN DIFFUSER

AIRFLOW/PRESSURE DROP
INFORMATION (INCHES W.C. [kPa])

NOTE: The location of the combination supply and return diffuser should
not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM
[472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level
for units with CFM greater than 1000 [472 L/s]. If the diffuser is installed
with a greater distance than recommended above, the supply air may
become stratified above the required comfort area causing uncomforta-
ble conditions.

*If a particular unit is to be converted to operate on LP (propane) for elevations above 2000 ft. [609.6 m] in Canada, the existing Natural Gas to LP Conversion Kits for the

subject models already contain the necessary orifices and instructions to de-rate the input for 2000-4500 ft. [609.6-1371.6 m] Canadian applications.

[