Figure 19: u-tube heater layout overview, 26 figure 19: u-tube heater layout overview legend – Roberts Gorden Gas-Fired User Manual

Page 32

Advertising
background image

CTH2-S

ERIES

I

NSTALLATION

, O

PERATION

AND

S

ERVICE

M

ANUAL

26

FIGURE 19: U-Tube Heater Layout Overview

LEGEND

a = 14" (36 cm)

reflector width (not shown)

b = 2" (5 cm)

end cap to burner

c = 2" (5 cm)

end cap to hanger

d = 7'6" (229 cm)

distance first hanger

e = 10' (305 cm)

distance between hangers

f = 5' (153 cm)

distance between last full tube

hanger and half tube hanger

g = 17.5" (44 cm)

burner length

h = 9.5" (24 cm)

burner height

*Requires the last reflector

before the U-Tube to be cut

in half for use on both sides.

**Requires the last tube before

the U-Tube to be cut in half for

use on both sides.

U-Tube

Burner

Reflector

Tube 10'

Tube/Reflector

Hanger
Coupling

Assembly

c

b

d

e

g

h

40' Tube Length

c

b

d

f

g

h

30' Tube Length

g

c

b

20' Tube Length*

h

e

Tube 5' **

**

Advertising