Ventilation

If you are mounting the CinemaWall in an enclosure, leave at least 2 inches (50 mm) of
space on all sides between it and surrounding objects, as shown in Figure 3-2. This allows
heat to disperse, maintaining the proper operating temperature.

Figure 3-2. Ventilation Requirements for Enclosure Mounting

Other Considerations

Other considerations and tips that can help improve your installation, avoid damage and
prolong operating life:

• Keep the ambient temperature constant and below 35°C (95°F). Keep the display away

from heating and/or air conditioning vents. Changes in temperature may cause drifts in
the display circuitry, which may affect performance.

• Keep the CinemaWall away from devices that radiate electromagnetic energy such as

motors and transformers. Common sources of these include slide projectors,
speakers, power amplifiers and elevators.

• Handle the unit carefully when installing it. When carrying it, use the built-in handles; DO

NOT touch or hold the screen face.

• Set the unit away from heat, excessive dust, and direct sunlight.

• Protect the inside of the unit from liquids and small metal objects. In case of accident,

unplug the power cord and have it serviced by an authorized Runco Service Center.

• Do not hit or scratch the panel surface as this causes flaws on the surface of the

screen.

• For correct installation and mounting it is strongly recommended to use a trained,

authorized dealer.

• To avoid sulfurization, it is strongly recommended not to place the unit in a dressing

room in a public bath or hot spring bath.

50

mm

(2")

50

mm

(2")

50

mm

(2")

Wall

Wall

50

mm

(2")

50

mm

(2")