Horizontal vent terminal location – Rheem AP13945-2 User Manual

Page 11

Advertising
background image

11

D

V

V

E

FIXED
CLOS

ED

OPE

RAB

LE

OPE

RAB

LE

FIXE

D

CLOS

ED

v

v

B

L

F

C

B

v

v

v

X

B

B

B

A

J

C

I

H

X

v

M

K

v

G

A

The following information should be used for determining the proper location of the vent terminal
for direct vent tankless water heaters.

V V

VE

EN

NT

T T

TE

ER

RM

MIIN

NA

ALL

X A

AIIR

R S

SU

UP

PP

PLLY

Y IIN

NLLE

ET

T

A

AR

RE

EA

A W

WH

HE

ER

RE

E T

TE

ER

RM

MIIN

NA

ALL IIS

S N

NO

OT

T P

PE

ER

RM

MIIT

TT

TE

ED

D

Horizontal Vent Terminal Location

C

Caannaaddiiaann IInnssttaallllaattiioonnss

1

U

US

S IInnssttaallllaattiioonnss

2

1 In accordance with current CAN/CGA-B149 Installation Codes.
2 In accordance with current ANSI Z223.1/ NFPA 54 National Fuel Gas Code.

+ A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and

serves both dwellings.

* If clearances are not specified then follow local installation codes and the requirement of the gas supplier.
** For condensing appliances: The vent for this appliance shall not terminate over public walkways, near soffit vents, crawl space
vents, of other areas where condensate or vapor could create a nuisance, hazard, or cause property damage. Where
condensate or vapor could cause damage or could be detrimental to the operation of regulators, relief valves, or other
equipment.

H = Clearance to each side of center line

extended meter/regulator assembly.
above

3 feet (91 cm) within a height 15 feet
(4.57 m) above the meter/regulator
assembly.

*

I = Clearance to service regulator vent

outlet.

3 feet (91 cm)

*

J = Clearance to nonmechanical air

supply inlet to the combustion air
inlet to any building or other
appliance.

6 inches (15 cm) for appliances < 10,000
Btuh (3 kW), 12 inches (30 cm) for
appliances > 10,000 Btuh (3kW) and
< 100,000 Btuh (30kW), 36 inches (91
cm) for appliances > 100,000 Btuh
(30kW).

6 inches (15 cm) for appliances < 10,000
Btuh (3 kW), 9 inches (23 cm) for
appliances > 10,000 Btuh (3 kW) and
< 50,000 Btuh (15 kW), 12 inches
(30 cm) for appliances > 50,000 Btuh
(15 kW).

K = Clearance to mechanical air supply

inlet.

6 feet (1.83 m)

3 feet (91 cm) above if within 10 feet

(3 m) horizontally.

L = Clearance above paved side walk or

paved driveway located on public
property.

Not allowed

Not allowed

M = Clearance under veranda, porch,

deck or balcony.

Not allowed

Not allowed

A= Clearance above grade, veranda,

porch, deck or balcony.

12 inches (30 cm) above anticipated

snow level.

12 inches (30 cm) above anticipated

snow level.

B= Clearance to window or door that

may be opened.

6 inches (15 cm) for appliances < 10,000
Btuh (3 kW), 12 inches (30 cm) for
appliances > 10,000 Btuh (3kW) and <
100,000 Btuh (30kW), 36 inches (91 cm)
for appliances > 100,000 Btuh (30kW).

6 inches (15 cm) for appliances < 10,000
Btuh (3 kW), 9 inches (23 cm) for
appliances > 10,000 Btuh (3 kW) and
< 50,000 Btuh (15 kW), 12 inches
(30 cm) for appliances > 50,000 Btuh
(15 kW).

C= Clearance to permanently closed

window.

*

*

D= Vertical Clearance to ventilated soffit

located above the terminal within a
horizontal distance of 2 feet (61 cm)
from the center line of the terminal.

*

*

E= Clearance to unventilated soffit.

*

*

F= Clearance to outside corner.

*

*

G= Clearance to inside corner.

*

*

Advertising