Specifications – Remington REMJ70 User Manual

Page 15

Advertising
background image

15

102961

REMJ70

REMJ150

Heat Output

(Kcal/hr)

17,640

38,500

Fuel Consumption

(liters/hr)

1.9

4.2

Fuel Tank Capacity

(liters)

16

47

Run Time per Tank

(hours)

8

11

Hot Air Output

(m

3

/min)

6.7@50Hz

12.4@50Hz

7.5@60Hz

13.7@60Hz

Voltage

100

100

Frequency (Hz)

50/60

50/60

Wattage (W)

200

340

Pump Pressure

(kg/cm

2

)

0.35@50Hz

0.35@50Hz

0.38@60Hz

0.37@60Hz

(PSI)

5.0@50Hz

5.0@50Hz

5.4@60Hz

5.3@60Hz

Fan

IMPORTANT:

Remove fan

from motor shaft before
removing motor from heater.
The weight of the motor
resting on the fan could
damage the fan pitch.

1. Remove upper shell (see

page 10).

2. Use 1/8" allen wrench to

loosen setscrew which
holds fan to motor shaft.

3. Slip fan off motor shaft.
4. Clean fan using a soft cloth

moistened with kerosene or
solvent.

5. Dry fan thoroughly.
6. Replace fan on motor

shaft. Place fan hub flush
with end of motor shaft
(see Figure 24).

7. Place setscrew on flat of

shaft. Tighten setscrew
firmly (40-50 inch-pounds/
4.5-5.6 n-m).

8. Replace fan guard and

upper shell.

SPECIFICATIONS

Figure 24 - Fan Cross Section

Setscrew

Motor
Shaft

Fan

Flush

Motor
Shaft

Setscrew

Fan

Figure 23 - Fan, Motor Shaft, and Setscrew Location

Advertising