Operation, Ventilation, Warning – Remington REMJ70 User Manual

Page 7

Advertising
background image

7

102961

WARNING

Review and understand the warnings in the

Safety

Information Section, page 3. They are needed to safely
operate this heater. Follow all local codes when using this
heater.

OPERATION

To Start Heater

1. Follow all ventilation and safety information.

2. Fill fuel tank with kerosene.

3. Attach fuel cap.

4.

Plug power cord into grounded receptacle with 100 Volts, 50 or 60 Hz.

5. Turn ON/OFF switch to "ON".

Extension Cord Wire Size Requirements

Up to 100 feet (30.5 meters) long, use 16 AWG (1.0 mm

2

) conductor

101 to 200 feet (30.6 to 61 meters) long, use 14 AWG (1.5 mm

2

) conductor

If heater does not start, push in flame-out control reset button (see Figures 5
and 6).

Continued

Figure 5 - Flame-Out Control Reset

Button (REMJ70)

Figure 6 - Flame-Out Control Reset

Button (REMJ150)

Flame-Out
Control
Reset
Button

Flame-
Out
Control
Reset
Button

Provide a fresh air opening of at least three square feet (2800 square cm) for each
100,000 Btu/Hr rating. Provide extra fresh air if more heaters are being used.

Example:

A 150,000 Btu/Hr heater requires one of the following:

• a two-car garage door (5 m wide opening) raised 8.6 cm.
• a single-car garage door (2.75 m wide opening) raised 15.3 cm.
• two, 76.2 cm wide windows raised 28 cm.

WARNING

Follow the minimum fresh, outside air ventilation
requirements. If proper fresh, outside air ventilation is not
provided, carbon monoxide poisoning can occur. Provide
proper fresh, outside air ventilation before running heater.

VENTILATION