INITIAL TESTING OF YOUR HR40:

You’re now ready to power up and test your HR40, but before you begin take
some time to sweep off your bench of any loose component leads or solder
splashes. A clean work area not only makes testing less frustrating but also
less prone to problems.

REQUIRED FOR INITIAL TESTING AND ALIGNMENT:

A known frequency standard in the 10MHz range such as:

Crystal oscillator or,

RF signal generator or,

Grid Dip oscillator or,

QRP transmitter such as a Ramsey QRP-40

A Ramsey frequency counter (CT-90, etc) or,

Any accurately calibrated receiver covering 40 meters

At the least, personal familiarity with the 40 Meter Ham band

And the following:

Coil alignment tool ( can be homemade per directions) and

9-volt battery, antenna earphones or a small speaker.

Connect the following:
ˆ

Fresh, 9-volt battery.

ˆ

Earphone or speaker.

ˆ

Antenna or at least a random length of wire.

ˆ

Adjust the three controls to the middle of their ranges.

ˆ

Press the power switch “on”. You should hear background noise
immediately, at least a gentle hiss.

ˆ

See if the volume control does its job, vary it and notice how the volume
changes.

ˆ

See if the RF gain control has some effect on what you hear.

ˆ

If everything seems ok so far, feel the tops of the two IC's with your finger.
Neither should feel hot or warm

ˆ

Slowly rotate the tuning control. At this point you may or may not hear
anything, since neither coil has been adjusted. If you do hear a few
whistles as you tune, the SA602 oscillator is working just fine.

ˆ

These simple initial checks verify that your receiver is operating well
enough to proceed to the next section, alignment.