Rockford Fosgate RFX9220M User Manual

Page 23

Advertising
background image

23

T

ROUBLESHOOTING

S

YMPTOM

D

IAGNOSIS

R

EMEDY

ERROR 1
(Initialize Error)

No initialization

Press the reset button

Mechanism is jammed and loading
motor (or driving circuit) is
defective

Repair the mechanism and
loading motor (or driving circuit)

ERROR 3
(Loading Error)

Foreign objects are preventing
the disc from loading

Check CDP mechanism load area by removing
faceplate and repair as necessary

Loading area in mechanism and
loading motor (or driving circuit) is
defective

Repair the mechanism and loading motor (or
driving circuit)

ERROR 4
(Eject Error)

Foreign objects are preventing disc
from ejecting

Check CDP mechanism eject area by removing
faceplate and repair as necessary

Eject area in mechanism and
ejecting motor (or driving circuit) is
defective

Repair the mechanism and loading motor (or
driving circuit)

ERROR 6
(Transverse
Error)

Transverse motor or switch is
defective or Traverse area of disc is
damaged

Check CD mechanism motor and switch.
Put in a different disc!

ERROR 7
(Servo Error)

Excessive dirt or dust on disc

Clean disc to remove dirt or dust as necessary

Disc is warped, cracked, damaged
or severely scratched

Put in a different disc!

ERROR 9
(TOC Error)

Disc is cracked, warped or severely
damaged

Put in a different disc!

Laser pickup is defective

Have service center repair laser pickup

Servo unit in CDP mechanism is
not operating properly

Check the servo circuit area and repair as
necessary

Radiated Noises

No RF suppression of blower
motors

Connect filter cap (Radio Shack #272-1085) in-line
on B+ near blower motor.

No RF suppression of switches

Connect a .1µf – .01µf non-polarized capacitor
across switch contacts

CD skips
excessively

Source unit mounted at an
incorrect angle

Check mounting angle of source unit (mount
within ±20˚ from horizontal) and repair as
necessary

Check tightness of installation sleeve and back
strap; repair or replace as necessary

Source unit not secured properly
(Standard Mount)

Source unit not secured properly
(ISO Mount)

Check tightness of mounting screws and repair or
replace as necessary

Advertising