Renaissance Group RB5C7748RR User Manual

Page 14

Advertising
background image

14

TECHNICAL DATA

R

888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com

Control Settings—RB5C7748R

Mechanical Settings

Pressure Settings – S/Contained

Differental

60

High Side Cut-In

260

Superheat

8-10

Control Settings

Set Point (Supply Air)

SP

27

Maximum Defrost Duration

dd

45

Hysteresis

HY

4

Dripping Time

dC

5

Low Setup Stop

LL

20

First Defrost After Power On

dU

OF

High Setup Stop

HL

50

Display During Defrost

dP

0

Anti-Short Cycle Delay

CC

3

Display Delay After Defrost

dr

20

Deep Freezing Time

Co 0

60

Digital Input Function

iF

0

High Temperature Alarm

AH

15

Digital Input Time Delay

id

10

Low Temperature Alarm

AL

-10

Fan Operating Function

FF

0

Alarm Differential

Ad

5

Fan Startup Delay (After Defrost)

Fd

0

Alarm Time Delay

At

30

Fan Startup Temperature After Defrost End

Fr

40

Defrost Type

dF

0

Sensor Failure Operation

SF

2

Defrost End Mode

dE

0

Temperature Sensor Offset

So

0

Defrost Termination Temperature

dt

45

Temperature Units Used

Un

1

Defrost Interval

di

6

Display Refresh Rate

PU

1

Electronic Controller