Renaissance Group RB5C7748RR User Manual

Page 5

Advertising
background image

R

888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com

START-UP AND OPERATION

Raise the Curved Glass

To raise the front curved glass, grab the lift
handle extrusion on the bottom edge of the
front curved glass and lift up.

Gas cylinders hold the glass open for hands
free access to the interior of the case.


Merchandiser Start-Up

Turn on the main power. Switch is on the
control panel at the rear right hand side of
base. Supply power will start evaporator coil
fan(s), the front fan and the evaporator/
condensate pan. It will supply power to the
light switch and thermostat, (self-contained
units).

From the front of the case, raise the deck
pans and check to see that the coil fans are
all functioning properly.

On the top of the front panel a register di-
rects air flow provided by the front fans,
(front air flow is to prevent condensation
from forming on the curved glass). Check
across the top of the front panel to see if air
is discharging across the entire front of the
case.

Turn on the lights. Light switch is in the rear
control panel. First time lighting may require
a short warm up period for the bulbs. Slightly
dim or a flickering of new bulbs is normal. If
lights do not turn on, check all of the race-
way plugs. The lighting is wired in series so
all lights must be plugged in or recepta-
cles capped in order for the case to light.


Temperature Settings

The case temperature is set at the factory, as
determined by the case size. The temperature is
controlled by a thermostat. If a temperature
setting change is required, follow the Johnson
Control Quick Reference page 14 of this man-
ual

5

Main Power

Thermostat

Lights

Lift Handle

Front Curved Glass

Deck Pan

Coil Fan

Front Fan

Register

Advertising
This manual is related to the following products: