If the wrong password is entered the display will flash NO for 5

seconds then return to normal.

3. Press

and

when the correct password is displayed.

The buttons will be unlocked.

Once the security has been disabled, a password needs to be recreated

to protect the settings.

Two Stage Systems

A 2nd stage is a second or additional system that will provide extra

heating or cooling. When a 2nd stage is operating the display will show

the number 2 by the heating and cooling icons.

A programmable temperature differential (default value is 2.0 F degrees or

1.0 C degree) and time delay (default value 20 minutes) control the 2nd

stage cycle.

The 2nd stage turns on when:

• The room temperature changes from the setpoint by the sum of the

1st and 2nd stage differential settings.

• The first stage has been on for the specified delay time, but the

heating/cooling demand has not yet been met.

Energy Efficient Recovery™

With Energy Efficient Recovery, the thermostat looks ahead to the next

event and attempts to reach the next setpoint at the exact time of the

event. If you have two stages, the thermostat will use only the first stage

during this period. This is more efficient than waiting until the next event

and then turning on both the first and second stages.

Backlit Display

This thermostat is equipped with a backlight to make viewing the display

easy. Press the

button to activate the backlight. The backlight will

turn off after 10 seconds of inactivity. If the thermostat is wired to have

the backlight stay on all the time the night light can be turned on/off in

the settings menu.

Overriding the Schedule

When the thermostat has been programmed, the settings and the

schedule are saved. The thermostat will follow the schedule unless an

override is entered.

Three methods of override are available.

Permanent Override

Press START/STOP SCHEDULE until the word SCHEDULE is not shown

on the display. The setpoint temperature is displayed. The thermostat

11