Setting the Fan to ON, AUTO, or CIRC

The fan has 3 settings: On, Auto, and Circ. Press the

button to switch

among the three.

ON: The fan is on constantly. The room temperture, set points, and status

of the heating and cooling equipment has no effect on the fan.

AUTO: When there is a call for heating or cooling the fan will turn on.

CIRC: The fan operates in a cycle of on for 10 minutes and off for 20

minutes. When there is a call for heating or cooling the cycle stops

and the fan responds to the call. The fan circulation cycle resumes

when the call for heating or cooling is satisfied.

Troubleshooting

14

System fan does not operate
properly.

Move fan option switch to either
gas or electric, to match system
(see Setting the Fan to ON, AUTO,
or CIRC
section).

Check F/C (Fahrenheit/Celsius) setting.
(see

T

To

o M

Ma

ak

ke

e C

Ch

ha

an

ng

ge

ess tto

o tth

he

e S

Se

ettttiin

ng

gss

section.

Thermostat does not display
proper room temperature.

Thermostat does not turn on system.

Check wiring (see

W

Wiirriin

ng

g D

Diia

ag

grra

am

mss

section in the Installation Manual).

Increase temperature differential
(see

T

To

o M

Ma

ak

ke

e C

Ch

ha

an

ng

ge

ess tto

o tth

he

e S

Se

ettttiin

ng

gss

section).

If problems with thermostat cannot be resolved, contact:

www.invensyscontrols.com

or

Technical Support: (800) 445-8299

System turns on too often.

Problem

Action

Display shows HI or LO and room
temperature is normal.

Call a licensed service person to
replace/repair.