Before You Call For Service…

Problem

Possible Causes

What To Do

Rumbling noise

Scale and sediment

Clean tank.

in tank.

Relief valve

Pressure build up

This is an unacceptable condition and must be

producing popping

caused by thermal

corrected. Contact the water supplier or plumbing

noise or draining

expansion to a

contractor. on how to correct this. Do not plug the

closed system.

relief valve outlet.

Rattling noise

Internal heat trap

This is normal for heat trap fittings when in operation

during periods of

fittings in operation.

and does not indicate a need for service.

water usage

Not enough or

Water usage may have

Wait for the water heater to recover after an abnormal

no hot water

exceeded the capacity

demand.

of the water heater.

Low gas pressure.

Check gas supply pressure and manifold pressure.

The pilot may be out.

Check the pilot. If necessary, relight using the
instructions in the Lighting the water heater section
of this manual.

The gas control (thermostat)

See the Temperature regulation of the water heater

may be set set too low.

section of this manual.

Leaking or open hot

Make sure all faucets are closed.

water faucets.

Cold water inlet

This is normal. The colder inlet water takes longer

temperature may be

to heat.

colder during the
winter months.

Water is too hot

The gas control (thermostat)

See the Temperature regulation of the water heater

is set too high.

section of this manual.

CAUTION: For your safety DO NOT attempt repair of gas piping, gas control (thermostat), burners, vent

connectors or other safety devices. Refer repairs to qualified service personnel.