Danger, Notice, Maintenance schedule – RIDGID OF45175A User Manual

Page 15

Advertising
background image

1. When not in use, compressor should be

stored in a cool dry place.

2. Tank should be drained of moisture.

3. Hose should be disconnected and hung

open ends down to allow any moisture
to drain.

15

The tank should be carefully inspected at
a minimum of once a year. Look for
cracks forming near the welds. If a crack
is detected, remove pressure from tank
immediately and replace.

Tank

Never attempt to repair or modi-
fy a tank! Welding, drilling or
any other modification will
weaken the tank resulting in
damage from rupture or explo-
sion. Always replace worn,
cracked or damaged tanks.

!

DANGER:

Drain liquid from tank daily.

NOTICE:

To change a filter, pull off the filter housing
cover. If filter element is dirty, replace ele-
ment or entire filter.

Filter Removal, Inspection and Replacement

This is an oilless type compressor requir-
ing no lubrication.

Lubrication

Storage

Operation

Daily

Weekly

Drain Tank

Check Air Filter

Check Safety Valve

Blow Dirt From Inside Motor

Maintenance Schedule