TROUBLE

PROBABLE CAUSE

REMEDY

Thermal overload
protector cuts out
repeatedly

Air tank pressure
drops when com-
pressor shuts off

Excessive moisture
in discharge air

Compressor runs
continuously

Compressor vibrates

Air output lower than
normal

1. Low voltage
2. Clogged air filter

3. Lack of proper ventila-

tion/room temperature
too high

4. Unit is plugged into

extension cord

1. Loose connections (fit-

tings, tubing, etc.)

2. Loose drain lock
3. Check valve leaking

1. Excessive water in air

tank

2. High humidity

1. Defective pressure

switch

2. Excessive air usage

Loose mounting bolts

1. Broken inlet valves

2. Intake filter dirty

3. Connections leaking

1. Check with voltmeter
2. Clean filter (see

Maintenance section)

3. Move compressor to well

ventilated area

4. Remove extension cord

1. Check all connections with

soap and water solution
and tighten

2. Tighten
3. Disassemble check valve

assembly, clean or replace

Do not disassemble
check valve with air in
tank; bleed tank

1. Drain tank

2. Move to area of less

humidity; use air line filter

1. Replace switch

2. Decrease air usage; com-

pressor not large enough
for a requirement

Tighten

1. Have authorized service

representative repair unit

2. Clean or replace intake fil-

ter

3. Tighten connections

!