Dehumidify – Robertshaw 9825I2 User Manual

Page 16

Advertising
background image

16

DEHUMIDIFY

Choose Dehumidify from the Main Menu.

The three items available in this menu are explained below.

Mode choices are:
Off – Humidity level will not be controlled through the thermostat.
With Cooling – Dehumidification will occur only during a cooling cycle and when the indoor
humidity level rises 2% above the humidity setpoint.
Independent Of Cooling – Dehumidification will occur when the measured humidity level rises
2% above the humidity setpoint regardless of a call for cooling.

NOTE: If Mode is set to Independent of Cooling, Over Cooling will be an option on the
Dehumidify Menu.

Over Cooling – To achieve more dehumidification, the thermostat will allow cooling beyond the
temperature setpoint by the entered amount. Range 0.5°F to 2.0°F.

Dehumidify Above – This is where you set your preference of the humidity level. The range is
45% to 60%.

Add-on – Cycles the dehumidifier regardless of a call for cooling. In order to get full use of
this mode, it should only be selected when a duct mounted dehumidifier is installed.

NOTE: When dehumidification is active, the main screen will
include the

icon next to the measured humidity.

Main Menu

Back

Select

Time & Day
Humidify

Dehumidify

Comfort Settings

Dehumidify Menu

Back

Select

Mode

Off

Dehumidify Above

50%

Dehumidify Menu

Back

Select

Mode Independent...

Over Cooling

1.5°F

Dehumidify Above

50%

Mode

Menu

Set At 70

9:15

AM

Monday Jun

20

55%RH

68

.9

Outside 42

°F

Select Dehumidify Mode

Cancel

Accept

With Cooling
Independent Of Cooling

Add-on