General information, Maintenance – Reliance Water Heaters RUF 100 199 SERIES 101 User Manual

Page 21

Advertising
background image

21

WARNING

UNDER NO CIRCUMSTANCES SHOULD THE INPUT EXCEED THE

RATE SHOWN ON THE HEATER RATING PLATE. OVER FIRING COULD

RESULT IN DAMAGE OR SOOTING OF THE HEATER.

CATHODIC PROTECTION

CAUTION

HYDROGEN GAS CAN BE PRODUCED IN A HOT WATER SYSTEM

SERVED BY THIS HEATER THAT HAS NOT BEEN USED FOR A LONG

PERIOD OF TIME (GENERALLY TWO WEEKS OR MORE). HYDROGEN

GAS IS EXTREMELY FLAMMABLE.

To reduce the risk of injury under

these conditions, it is recommended that a hot water faucet be opened

for several minutes before using any electrical appliance connected to

the hot water system. If hydrogen is present, there will probably be an

unusual sound such as air escaping through the pipe as the water begins

to flow. There should be no smoking or open flame near the faucet at

the time it is open.

PRECAUTIONS

IF THE UNIT IS EXPOSED TO THE FOLLOWING, DO NOT OPERATE

HEATER UNTIL ALL CORRECTIVE STEPS HAVE BEEN MADE BY A

QUALIFIED SERVICEMAN.

1. FLOODING TO OR ABOVE THE LEVEL OF THE BURNER OR CONTROLS

2. EXTERNAL FIRING

3. DAMAGE

4. FIRING WITHOUT WATER

5. SOOTING

NEVER OPERATE THE HEATER WITHOUT FIRST BEING CERTAIN IT IS

FILLED WITH WATER AND A TEMPERATURE AND PRESSURE RELIEF

VALVE IS INSTALLED IN THE RELIEF VALVE OPENING OF THE HEATER.

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF,

TURN OFF THE MANUAL GAS CONTROL VALVE TO THE APPLIANCE.

GENERAL INFORMATION

POWER BURNER

The initial start-up procedure of the unit is provided on page 20.

TABLE 4

GAS SUPPLY

SPECIFICATIONS

Natural

Gas 199

Propane

Gas 199

Maximum Gas Supply Pressure

10. 5” WC

(2.59kpa)

14.CTWC

(3.45kpa)

Nominal Gas Supply Pressure

7.0” WC

(1 .74Kpa)

11.0”WC

(2.74Kpa)

Minimum Gas Supply Pressure

4.8” WC

(1.18Kpa)

8.5” WC

(2.08 Kpa)

Manifold Pressure

0” WC

(OKpa)

0” WC

(OKpa)

HIGH ALTITUDE INSTALLATIONS

WARNING

THESE HEATERS ARE CERTIFIED FOR USE WITHOUT MODIFICATION
FOR ALTITUDES UP TO 10,100 ft. (3078 m). INSTALLATIONS ABOVE

THESE ALTITUDES MAY REQUIRE REPLACEMENT OF THE BURNER
ORIFICE. CALL THE TECHNICAL CENTER @ (800) 527-1953 FOR
REQUIREMENTS.

Some gas utility companies derate their gas for altitude, making it unnecessary
to install high altitude orifices. Call the local gas or utility company to verify
BTU content.

Due to the input rating reduction at high altitudes, the output rating of the
appliance is also reduced and should be compensated for in the sizing of
the equipment for applications.

MAINTENANCE

GENERAL

KEEP APPLIANCE AREA CLEAR AND FREE FROM COMBUSTIBLE
MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS
AND LIQUIDS. (SEE WARNING ON PAGE 5, LOCATING THE
HEATER).

Water heater maintenance includes periodic tank flushing and cleaning, and
removal of lime scale. The unit should be inspected and adjusted to maintain
proper combustion. Refer to the following table. A periodic inspection of the
venting system should be made. Where used, the water circulating pump
should be oiled.

MAINTENANCE SCHEDULE

Following are the instructions for performing some of the recommended
maintenance. Unit inspection and adjustment should be performed by a
competent technician.

COMPONENT OPERATION INTERVAL

REQUIRED

Tank

Sediment

Monthly

Flushing

Removal

Tank

Lime Scale

Semi

UN-LIME

®

Removal

Annually

Delimer

Relief Valve

Inspect

Semi

Annually

Clean Inlet

Blower

Screen and

As Required

Soft Brush

Blower Wheel

Vent System

Inspect

Every 3

Joints should

Months

be sealed

Advertising
This manual is related to the following products: