Regency U38 ULTIMATE Freestanding Gas Stove

LOG SET

INSTALLATION

Read the instructions below carefully
and refer to the diagrams. If logs are
broken do not use the unit until they are
replaced. Broken logs can interfere with
the pilot operation.

The gas log kit contains the following:

a) 02-65

Rear Log

902-267

b) 02-56

Middle Left Log

902-230

c) 02-44

Front Left Log

902-228

d) 02-46

Left Top Log

902-231

e ) 02-45

Front Right Log

902-229

f)

02-47

Center Log

902-232

g) 02-48

Middle Right Log

902-226

h)

Embers

902-151

i)

Lava

902-154

Note: Install Optional Brick Panels prior

to installing logs.

Embers.

Embers

The "02" refer numbers (i.e. 02-65) are

molded into the rear of each log.

1) Carefully remove the logs from the box and

unwrap them. The logs are fragile, handle
with care - do not force into position.

2) Sprinkle the embers on the left and right

sides of the firebox base.

CONVERSION TO LOWER BTU RATING FOR U38

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS

FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

Natural Gas Conversion Kit 730-920
Contains:
Qty. Part #

Description

1

904-240 Burner Orifice #37 (Natural Gas)

1

918-034 Decal "Converted to 30,000 Btu"

1

918-033 Instruction Sheet

Propane Conversion Kit 730-922
Contains:
Qty. Part #

Description

1

904-390 Burner Orifice #52 (Propane)

1

918-034 Decal "Converted to 30,000 Btu"

1

918-033 Instruction Sheet

1) Shut off the gas supply.

2) Open the front door. Carefully remove the

logs and lava rock.

3) Remove burner. See diagram below.

Burner Orifice

Note: Use a
magnetic type
screwdriver if possible.

Move Rear Log

Pins forward to

front holes.

Vent Restrictor setting at High 40,000 Btu/h

Vent Restrictor setting at Low 30,000 Btu/h

INSTALLATION

4) Unscrew the 2 Rear

Log Pins and move
to the front hole
position.

5) Remove Rear Log

Bracket and slide
the Log Bracket Re-
strictor between
the Rear Log Brack-
et and the burner,
secure with the 2
screws.

7) Reinstall new burner orifice (NG stamped

#37 or LP stamped #52) and tighten.

8) Reverse steps 3) and 2).

9) Adjust Vent restrictor setting: To set the

Vent restriction as indicated in the diagram,
simply loosen the screws and push the vent
restrictor plate to the correct position. Tight-
en the screws.

Unit

Btu/h

Restrictor Opening

U38

40,000

A 1-3/8" (35mm)

U38

30,000

B 1-1/8" (29mm)

6) Remove burner orifice with a 1/2" wrench

and discard.

10) Attach the label "This unit has been convert-

ed to..." on top of the Serial # decal over the
higher Btu information.

11) Check for gas leaks.

12) Check inlet and outlet pressures.

13) Check operation of flame control. Check for

proper flame appearance and glow on logs.