Installation, Conversion from natual gas to propane – Regency Wraps U38-LP User Manual

Page 9

Advertising
background image

Regency U38 ULTIMATE Freestanding Gas Heater

9

INSTALLATION

Installer Notice:
These instructions must be left
with the appliance.

Burner Orifice

CONVERSION FROM NATUAL GAS TO PROPANE

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

Conversion Kit 730-969 Contains:

Qty. Part #

Description

1 910-018

SIT Conversion Kit-
50% Turndown LP

1 910-037

LP Injector (Pilot Orifice)

1 904-641

Burner Orifice #50

1 908-528

Red "PROPANE" label

1 908-255

Label "Converted to Propane"

1 918-032

Instruction Sheet

1) Shut off the gas supply.

2) Open the front door and carefully remove

the logs and lava rock.

3) Remove burner. See diagram below.

Pilot assembly is now accessible for

steps 4) to 9).

Note: Use a magnetic type screwdriver if pos-

sible.

4) Remove and discard the 3 pressure regu-

lator mounting screws (A), pressure reg-
ulator tower (B) and diaphragm (C).

5) Insure that the rubber gasket (D) is properly

positioned and install the new HI/LO pres-
sure regulator assembly to the valve using
the new screws (E) supplied with the kit.
Tighten screws securely.

6) Pull off the pilot cap to expose the pilot

orifice.

7) Unscrew the pilot orifice with the allen key

and replace with the LP pilot orifice in the kit.

8) Remove burner orifice with a 1/2" wrench

and discard. Use a wrench to hold on to the
elbow behind the orifice.

9) Reinstall new burner orifice LP stamped

#50 and tighten.

10) Reverse steps 3) to 2).

11) Attach the Conversion label "This unit has

been converted to Propane" on top of the
Serial # decal.

12) Replace yellow "Natural Gas" label with red

"Propane" label

13) Check for gas leaks.

14) Check inlet and outlet pressures.

15) Check operation of flame control.

16) Check for proper flame appearance and

glow on logs.

Advertising