Chapter 2 Installation and Setup

IPmux-11 Ver. 2.00

Connecting IPmux-11 to Power

2-5

Before connecting or disconnecting any cable, the protective earth terminals of
this unit must be connected to the protective ground conductor of the mains
(AC or DC) power cord. If you are using an extension cord (power cable) make
sure it is grounded as well.
Any interruption of the protective (grounding) conductor (inside or outside the
instrument) or disconnecting of the protective earth terminal can make this
unit dangerous. Intentional interruption is prohibited.

Connecting AC Power

AC power is supplied to IPmux-11 via a 1.5m (5 ft) standard power cable
terminated by a standard 3-prong socket. A cable is provided with the unit.

To connect AC power:
1. Connect the power cable to the power connector on the IPmux-11 rear panel.
2. Connect the power cable to the mains outlet.

The unit turns on automatically upon connection to the mains.

Connecting DC Power

A special IEC 60320 adapter for the -40/-60 VDC power connection is supplied
with the unit.

To connect DC power:
• Refer to the DC power supply connection supplement for instructions how to

wire the DC adapters, and to the

Handling Energized Products

section.

Warning