Maintenance / service – Rinnai RHFE-1004FA User Manual

Page 36

Advertising
background image

– 34 –

MAINTENANCE / SERVICE

MAINTENANCE SUGGESTIONS

This heater has been designed and constructed for
a long performance life when installed and operated
properly under normal conditions. Regular
inspections, as outlined in this section, are strongly
recommended as means of keeping your heater
operating efficiently throughout the season.

1. Cleaning

Heater must be cleaned annually. Keep heater
clear of dust and debris especially in and around
burner.
Cleaning procedures of heater are as follows:

1) Turn heater off. Allow to cool for one hour.
2) Remove the Front Panel by removing

screws. See schematic page 38.

3) Use pressurized air to remove dust from

around main burner, heat exchangers and
fan blades.

4) Use soft dry cloth to wipe cabinet.

DO NOT DAMAGE OR DISTORT ANY PARTS OF
HEATER.

DO NOT USE WET CLOTH OR SPRAY
CLEANERS ON BURNER.

2. Visual check of main burner flames.

Flame pattern should be as shown in the
following Figures.
The burner must flame evenly over the entire
surface when operating correctly. The flame
must burn with a clear blue stable flame. See
page 40 item # 417 for location of view ports.
Any and all parts removed for inspection or
service must be replaced before operating unit.

3. The appliance area must be kept clear and free

from combustible materials, gasoline and other
flammable vapors and liquids.

4. The flow of combustion and ventilation air should

not be obstructed.

5. Verify proper operation after servicing.

VENT MAINTENANCE

VENT SYSTEM
Must be checked annually for blockage or
deterioration. See vent installation
instructions for proper assembly.

MAINTENANCE ELECTRIC MOTORS
Motors are permanently lubricated and need
no lubrication. Keep fan and motor free of
dust and dirt. Clean annually.

VISUAL CHECK

SATISFACTORY

FRONT VIEW

UNSATISFACTORY

FRONT VIEW

Advertising