Raymarine ST6001 User Manual

Page 14

Advertising
background image

8

ST6001+ Smartpilot Controller Operating Guide

Note: The

RESPONSE screen is set as a default data page (see SmartPilot

Commissioning Guide) so you can also access it by pressing

disp and then

scrolling through the data pages.

2. Press -1 or +1 to change the response level.

3. Press disp or wait for 5 seconds to return to the previous display.

Adjusting performance – Non-G systems
Non-G SmartPilot systems have three different response levels:

Response Level 1: AutoSeastate on (Automatic deadband)

The SmartPilot will gradually ignore repetitive boat movements and
only react to true variations in course. This provides the best compro-
mise between power consumption and course keeping accuracy

Response Level 2: AutoSeastate off (Minimum deadband)

This setting provides tighter course keeping but will lead to increased
power consumption and drive unit activity

Response Level 3: AutoSeastate off + yaw damping

This setting provides the tightest possible course keeping by introducing
counter rudder yaw damping You can adjust the counter rudder setting in
Dealer Calibration (see SmartPilot Commissioning Guide)

To make a temporary change to the response setting:

1. Display the RESPONSE screen by pressing the -1 and +1 keys together

2. Press -1 or +1 to change the response between levels 1 to 3.

3. Press disp or wait for 5 seconds to return to the previous display.

Note: You will lose these temporary changes to response level whenever the
system is powered off. You can make permanent adjustments in User Cali-
bration (see page 23).

D5452-2

Increase
response

Decrease

response

Advertising