4 user calibration options, How do i access user calibration settings, User calibration pages – Raymarine ST6001 User Manual

Page 29: Autotack angle (sailboat only)

Advertising
background image

Chapter 2: Advanced Operation

23

2.4 User Calibration Options

The calibration information in this handbook relates to only those settings
that can be adjusted during normal operation (USER CAL). For information on
all available calibration settings, see SmartPilot Commissioning Guide.

Note: Many of the settings are sailboat specific and will only be displayed if
your vessel type is set to

SAILBOAT

How do I access User Calibration settings?

You can only access the calibration mode from Standby mode:

1. With the SmartPilot in Standby mode, press and hold the standby key

for 2 seconds. The display will change to show DISPLAY CAL.

2. Press the disp key once, the display will now show USER CAL.

3. Press auto to enter User Calibration.

The first page of User Calibration will now be displayed.

4. To access other User Calibration pages, press disp to scroll down

through the items within that grouping:

5. When you reach an item you wish to adjust, use the -1, +1, -10 and +10

keys (as appropriate) to change the value.

6. When you have made all the changes you want to make, press and hold

standby for two seconds to exit calibration mode and save changes.

User Calibration pages

AutoTack angle (SAILBOAT only)

The AutoTack angle is the angle through which the boat will turn when you
select an automatic tack.

Screen Text

Options

AUTO TACK

40° to 125° in 1° steps