If you do not follow these instructions exactly, a fire or explosion may

result causing property damage, personal injury or loss of life.

1

Rinnai America

FF Models

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

Lighting the Unit

1) This water heater does not have a pilot. It is equipped with a direct ignition

device which automatically lights the burner. DO NOT TRY TO LIGHT THE
BURNER BY HAND.

2) Before operating the Rinnai Water Heater smell all around the unit for gas.

Be sure to smell near the ground as leaking gas may settle there.

3) Turn the manual gas control valve on.

STOP!! READ THE SAFETY ISSUES ON PAGES 8

4) Turn on any hot water tap. The Rinnai Water Heater should light and begin

heating your water.

If the Rinnai Water Heater fails to light

1) DO NOT ATTEMPT TO LIGHT BY HAND.

2) Turn off the electrical power to the unit.

3) Turn off the manual gas control.

4) Wait 5 minutes, if you smell gas, go to a neighbor's house and call the gas

company or the fire department. If you do not smell gas, go to the next step.

5) Turn the manual gas control valve on.

6) Turn the electrical power to the unit on.

7) Turn on any hot water tap.

8) If the unit still fails to light, turn off the electricity and gas to the unit and call

Rinnai 1-800-621-9419.