Raritan Computer II User Manual

Page 20

Advertising
background image

10

P

ARAGON

II U

SER

M

ANUAL

1. Display Ver./SN (Firmware Version and Serial Number): Displays current version of firmware and

unit’s serial number.

Firmware: 2C1

SN: CPB80347

Figure 11 Display Ver. and SN

2. Test User UST1 (User Station): Used by administrator to check if user stations (UST1s) are

functioning properly. Press the [ ] or [ ] button to change user port number. Display will read “OK”,
“None”, or “Failed. Press [ESC] to return to normal display.”

If a “failed” condition is detected, make sure Category 5e UTP cable is installed properly and secured,
or try using another UST1 to see if UST1 under test has become defective.

Test User UST1

UST1: 3 OK

Figure 12 User Station Test

3. Test Channel UKVM (CIM UKVM): Used by administrator to check if CIM is functioning properly.

Press the [ ] or [ ] button to change channel number. Display will read “OK”, “None”, or “Failed.”
Press [ESC] to return to normal display.

If a “failed” condition is detected, make sure Category 5e UTP cable is installed properly and secured,
or try using another CIM (UKVM) to see if CIM under test has become defective.

Test Chan. UKVM

UKVM: 60 OK

Figure 13 Channel CIM (UKVM) Test

4. Test Stack Unit: Press the [ ] or [ ] button to select the corresponding Stacking Unit ID for any

connected units. If there are no Stacking Units connected, the LCD will display “None”. If there are
Stacking Units connected, the LCD should read “Ok” for each unit. Press [ESC] to return to normal
display.


5. Stacking Support: Press the [ ] or [ ] button to set the Stacking Unit ID number (0 – 3 for a P2-

UMT832M or “0” or “1” for a P2-UMT1664M). The default is set to “0” (no Stacking Units
connected). If you wish to add Stacking Units, this number must be equal to the number of Stacking
Units connected. Press [ESC] to return to normal display.

Stacking Support

Unit(s): 0-3

Figure 14 Stacking Support

6. Set LCD Contrast: Modifies contrast level of front panel LCD Display. Press the [ ] or [ ] button to

increase or decrease contrast, and press the [ESC] button to return to normal display.

Set LCD Contrast

Use Up/Down Keys

Figure 15 Set LCD Contrast

Note: LCD contrast can also be adjusted by holding the [

] button and pressing the [ ] or [ ] button at

any time.