temperature climbs above a set limit and the
'overheat' light will come on. This cut-out
which gives an audible click, may also
operate due to residual heat when the shower
is switched off. It will reset itself if cold water
is run through the shower for 10 to 20
seconds and the 'overheat' light will go out.

8. A pressure relief device is fitted to safeguard

against extreme abuse conditions.

9. There are three defined plate spray settings

adjustable by rotating the spray plate (see
diagram 4). If desired many combinations
between the 3 can be achieved.

HOW TO MAINTAIN YOUR
'REDRING' SHOWER

All water contains particles of lime which build up
in the showerhead and unit reducing the
performance. It is therefore important to clean the
showerhead by regularly dipping it in a suitable
de-scaling solution. The frequency of this will vary
from weekly to quarterly.

Check the srayplate is then free to rotate to give
the three setting. In some winter conditions,
when incoming water from the cold water storage
cistern is particularly cold it may be necessary to
select the inner or outer spray pattern only. This
will ensure correct operation of the shower with a
slightly lower water flow rate.

NOTE:
After use it is normal for some water to drip from
the shower head for a few moments.

Cleaning

It is recommended that the shower unit and
accessories are cleaned using a soft cloth.

DO NOT use powerful abrasive or solvent
cleaning fluids. It is advisable to switch off the
shower at the isolating switch to avoid the
shower accidently switching on.

WHAT TO DO IF THINGS GO
WRONG

Self Help

If the performance of the shower does deteriorate
in service make the following checks before
calling out the contractor. Any one of these
simple adjustments could restore the
performance.

Diagram 4

'CASCADE'
(inner/outer)

'SURF'
(outer spray
only)

'SPORT'
(inner spray
only)

Diagram 5

The spray head rotates
through approximately 140

o

IN ORDER TO MAINTAIN THE
PERFORMANCE OF YOUR
SHOWER YOU MUST CLEAN
THE SHOWERHEAD.

Increase water flow by
adjusting the temperature
control (knob B) anti-clockwise
to a lower number on the
temperature scale.
Clean the showerhead.
Switch power to '

low

power ' setting .
Select outer or combination
spray pattern.
Increase pressure of water
supply e.g. fully open service
valve.
Check hose is not kinked
restricting the water flow.

a) Water too

HOT

4

a)

b)

c)

Advertising