Raritan Engineering 1700 Series User Manual

Page 2

Advertising
background image

2

Incorporate this inspection into commissioning
procedure in spring and winterizing procedure in fall.

A removable magnesium Anode is integral with the
hot water discharge fitting. The Anode should be
checked at least once a year by removing it from the
water heater. If the Anode diameter is less than 3/8"
(9.5mm), it should be replaced. If discoloration,
unusual smell or taste develop in the water, inspect or
replace Anode. The Anode is replaceable as a unit
and may be ordered from Raritan dealers or from the
factory. Please specify 6, 12, or 20 gallon model.

Replacing the thermostat:

WARNING: Danger of shock. Be sure to turn
power off.

Use ONLY Raritan replacement thermostat
(#WH16 - ignition protected).

1. Remove access panel to thermostat and element.

2. Remove personnel protector.

3. Unscrew the neutral and hot wires from the

element with a Phillips screw driver.

4. Cut the incoming wires. Using fingers pull tabs

of thermostat mounting bracket forward and lift
thermostat out.

5. Install new thermostat.

6. Strip incoming wires, exposing 5/16"(8mm) of

wire.

7. Crimp neutral wire supply to white wire and hot

wire supply to black wire (series connector
provided with new thermostat).

8. Screw ring terminals of white and black wires on

lower side of thermostat to studs of the element.

9. Reinstall personal protector panel.

NOTE: Check for leaks before proceeding.

10. Replace access panel.

11. Turn on AC power.

Replacing The Heating Element:

WARNING: Danger of shock. Be sure to turn
power off.

1. Turn off water pressure pump and open all hot

water faucets. When water has stopped flowing,
pressure in water heater has been relieved.

2. Drain heater the rest of the way either through the

drain valve, if installed, or by removing the cold
water supply hose at the bottom of the tank.

3. Remove electrical access cover, personnel

protector and two wires connected to heating
element. Do not remove ground wire. Unscrew
and remove Heating Element using 1½" socket
wrench, discarding gasket. Never reuse an old
gasket.

4. Install new gasket and Heating Element.

5. Reconnect black and white wires to the new

Heating Element and install personnel protector
and electrical access cover.

Fig. #1

Typical Hookup, Raritan Water Pressure System and Water Heater

Hot

Cold

Drain for Temperature

and Pressure Valve

Drain Valve

or Drain

Plug

Galley Flow

System

Expansion

Tank

Dockside

Water Hose

Freshwater Tank

Fill Fitting

on Deck

Connector Fitting with

Built-in Regulator

Shutoff

Valve

Check

Valve

To Shore

Power

(AC Service)

Engine

Coolant

IN

Engine

Coolant

OUT

Cold Water Faucet

Hot Water Faucet

Water Heater

2

VacuumBreak

(Backflow Preventor)

Advertising