Paging input, Paging inhibit, Multi-room system controller rmz-955 – ROTEL RMZ-955 User Manual

Page 14

Advertising
background image

MULTI-ROOM SYSTEM CONTROLLER RMZ-955

14

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Paging Input

The paging input allows announcements to be made over the
system, and, if required, for Zones to be momentarily muted, in
conjunction with a doorbell or a phone system.

The paging feature needs to be activated from an external
source via the “paging trigger” RCA-type input jack on the back
of the RMZ-955. Any device which shorts the trigger input will
cause the controller to enter its paging mode. For example, a
doorbell, a phone system , or a keyed announcement micro-
phone system could provide this control.

The “Paging Audio In” RCA jack is connected to the audio output
of the announcement system (phone or microphone amplifier).

The “Paging Audio Output” jack can be connected to the Paging
Audio Input on a second controller (in a large multi-controller
system) or to the RCA input of an external amplifier.

INPUTS

OUT

IN

OUT

IN

OUT

MULTI-Z

M

POWE

DESIG

UNSWITCHED

100W MAX AC 120V 60HZ

SWITCHED (RLC-900)

100W MAX AC 120V 60HZ

SPEAKERS

ZONE D

DATA

1 2 3 4 5 6

PRE-

PAGING

TRIGGER

AUDIO IN

AUDIO OUT

3

4

+ –

+

LEFT RIGHT

Door Bell

Microphone

Amplifier

Phone

System

Relay

(if required)

trigger

trigger

audio

paging audio output to

paging audio input

on second RMZ-955

Paging Inhibit

The paging function is individually configurable for each zone.
The installer can select which Zones will receive or not receive
an announcement when the paging is activated. Each Zone has
an internal micro switch which is used to set the paging function
ON/OFF for that zone. These switches are accessed by removing
the top cover of the RMZ-955 by a qualified technician. Make
sure that the AC power line is disconnected before removing
the cover.

ZONE A

ZONE B

ZONE C

ZONE D

PAGING ON

PAGING OFF

RMZ-955 Circuit Board

back

front

Notes:
If a Zone is in Standby (or is listening to Input 1, 2, or 3) and its
paging switch is set to OFF, the Zone will remain in its present
status when the paging is activated for the rest of the system. It
will not be muted and no announcement will be heard.

If a Zone is listening to Input 4, the paging input will be heard
when activated, regardless of whether its paging switch is set to
ON or OFF.