Warning, 2004 roberts-gordon – Roberts Gorden GordonRay BH-175 User Manual

Page 35

Advertising
background image

ROBERTS GOR DON

®

BH- S

ERI E S

S

UBM IT TAL

S

HE E T

© 2004 Roberts-Gordon

BEFORE IN ST AL LATI ON AND OPER ATI ON OF HEATI NG E QUIPMENT, READ AND U NDERSTAND T HE INSTALL AT ION, OPERATIO N AND SERVICE MANUAL .
APPL ICATION S, ENGI NEE RING AND DET AI LE D GUID ANCE ON SYST EMS DE SIGN, INSTAL LATI ON AND PRODUCT PE RFORMANCE IS AVAI LABLE UPON RE QUEST. ROBERT S GORDON

®

PRODUCT S ARE T O BE

INSTAL LE D ONL Y IN ACCORDANCE WI TH L OCAL L AWS, CODES AND REGUL AT IONS, AND ONLY BY A CONT RACT OR QUALI FIE D I N THE I NST ALL AT ION AND SE RVICE OF GAS-FIRE D HE AT ING EQUI PME NT.

GAS PIPING

Gas Connection with Stainless Steel Flex Connector

WARNING

Fire Hazard

Tighten gas line fittings to connect gas supply

as shown below.

Flex gas line can crack when twisted.

Gas line moves during normal operation.

Failure to follow these instructions can result in death,

injury or property damage.

45°

Burner Assembly

(shown without blower assembly)

Pipe Nipple

Burner

45°

Shut-Off Valve must be parallel to

burner gas inlet. The 2" (5 cm)

displacement shown is for the cold

condition. This displacement may

reduce when the system is fired.

Shut-Off Valve

(included

with connector)

Stainless Steel Flex

Gas Connector

90 ° Pipe Elbow

(not included)

Burner

2" (5 cm)

12"

(30 cm)

Hold gas nipple securely
with pipe wrench when
attaching the flex gas
connector.

Failure to follow these
instructions can result in
product damage.

Description

Par t Number

1/ 2” Flex Gas Line

91412200

3/ 4” Flex Gas Line

91412203

Advertising
This manual is related to the following products: