Symptom diagnosis remedy – Rockford Fosgate 1000 User Manual

Page 34

Advertising
background image

– 29 –

Speaker Output
Low or Distorted

Readjust input gains of amplifier.

Check system with known work-
ing source and repair or replace
original source as needed.

Check the alternator, battery,
fuse, and power and ground
wiring. Repair as necessary.

Symptom

Diagnosis

Remedy

Input gain signal for amplifier
is incorrectly set.

Source unit output too low or
source unit has no output.

Low battery voltage or large
voltage drops to the amplifier
under load.

Amplifier Noise

(Turn-on Pop)

Voltage spike from output of
preceding component is en-
tering amplifier through in-
put signal.

Voltage spike from remote
turn-on lead is entering
through REM input terminal.

Disconnect input signal to
amplifier and turn amplifier
on and off. If noise is elimi-
nated, connect REM lead of
amplifier to source unit with
a delay turn-on module.

Use a different 12 volt source
for REM lead of amplifier
(i.e., battery direct). If noise
is eliminated, use a relay to
isolate amplifier from noisy
turn-on output.

TROUBLE- S

H
O
O

T

I

N
G

?

Advertising
This manual is related to the following products:

360, 400