Fault codes – Rinnai RHFE-750ETR User Manual

Page 14

Advertising
background image

14

Rinnai Corporation RHFE-750ETR

Fault

Codes

If there is a malfunction the appliance may shut down as a safety precaution and display a fault code to assist in
diagnosing the problem. The fault code will flash in the Fault Code Display window and the Operation Indicator
will flash green.

Code

Fault

Remedy

11 Ignition

failure

Confirm that the gas supply is turned on. Switch appliance to
STANDBY and then ON again. If ignition failure continues
then a Service call is required.

12 Incomplete

combustion

Service

call

14

Filter blocked or Overheat

Clean filters
If overheating continues then a service call is required to
determine the cause.
Thermal fuse; a qualified service technician must replace the
fuse following the procedure below.

16 Room

overheat

The temperature has reached 104° F (40° C). Turn the
appliance off or engage the AUTO OFF function to prevent the
display of flame. See AUTO OFF section.

31

Room temperature sensor faulty

Service call

32

Overheat temperature sensor faulty

Service call

53

Spark sensor faulty Service

call

61

Fan motor faulty

Service call

71 Solenoids

faulty

Service

call

72

Flame detection circuit fault

Service call

73 Communication

fault

Service

call

99

Flue block

Check around flue terminal for obstructions to air flow

The cause of the overheat condition needs to be
determined and remedied before replacing the
thermal fuse.

A qualified service technician needs to:

1. Disconnect the appliance from the power supply.

2. Remove the right hand side panel to allow access

to the gas control and main PCB.

3. Unplug the thermal fuse harness (including the

control plug for the POV on the gas control) and
unscrew thermal fuse.

4. Re-assemble with replacement thermal fuse.

PCB

POV

Thermal Fuse

Replacement of Thermal Fuse

Advertising