Specifications – Rinnai RHFE-750ETR User Manual

Page 4

Advertising
background image

4

Rinnai Corporation RHFE-750ETR

Application

Inbuilt only; for residential installation, commercial setting, or manufactured
home;
not designed for installation in a solid-fuel burning fireplace

General Description

Inbuilt convector, glass and steel fronted, ceramic log space heater with
forced convection and power flue system

Operation

Push button electronic / remote control

Gas Connection

Flex line is 3/8 inch flare nut;
ball valve is 1/2 inch female x 3/8 inch flare

Gas Control

Electronic

Burners Flame

burners

Temperature Control

Electronic thermostat

Logs Ceramic

Ignition System

Electronic spark ignition

Flue System

The flue must be terminated to atmosphere. Only flue components listed with
the appliance’s certification can be used. Warranty will be voided if non-listed
components are installed.

Fan 3

speed

Weight

154.3 lb (70 kg)

Electrical Connection

AC 120V, 60 Hz

Specifications

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.

Natural Gas

Propane Gas

Minimum supply gas pressure

4.3 in (109 mm) W.C.

9.8 in (249 mm) W.C.

Maximum supply gas pressure

10.5 in (267 mm) W.C.

13.0 in (330 mm) W.C.

Manifold test pressure

Factory Set

Factory Set

BTU/hour input

Natural Gas: Low - 10000 BTU/h; High - 29000 BTU/h
Propane:

Low - 10000 BTU/h; High - 28000 BTU/h

BTU/hour output

Natural Gas: Low - 7850 BTU/h; High - 21900 BTU/h
Propane:

Low - 8050 BTU/h; High - 21840 BTU/h