Installing the New Water Heater (cont’d)

13

“Fuel” Conversion Instructions

From Natural Gas To Propane

(L.P.) Gas

Read and follow detailed conversion instructions below and

also in the instruction manual in their entirety before starting

the conversion.
Conversion kit with necessary parts are in a bag attached to

the drain valve.

Step 1. Turn gas control knob “A” to “PILOT”. Depress and

turn “OFF”. (See Figure 4, page 14).

Step 2. Remove outer and inner access doors from water

heater.

Step 3. Remove burner assembly from water heater and con-

trol by loosening

3

4

″ nut “H” holding burner assem-

bly to control. (See Figure 5, page 14). Loosen pilot

tube nut “J” and thermocouple nut “K” at control.

Step 4. Remove screws “D” disengaging manifold from

burner. (See Figure 6, page 14)

Step 5. Remove orifice “E” (See Figure 6, page 14) using

3

8

wrench. Install orifice marked “L.P.” found in the

bag into manifold. Tighten securely. Secure burner

to manifold with screws “D”.

Step 6. Loosen pilot tube nut “F” (See Figure 7, page 14).

Remove orifice “G” and replace with red colored

orifice found in bag. Reinstall nut “F” and tighten

securely.

Step 7. Make sure all connections are tightened securely,

and reinstall burner assembly into water heater. Po-

sition end of the manifold inside bracket as shown in

Figure 6 on page 14. Reinstall manifold into control

and tighten

3

4

inch nut (“H”) securely. Recheck to see

that end of manifold is still inside bracket as shown

in Figure 6 on page 14. Reinstall pilot tubing and

thermocouple into control. (See Figure 5, page 14)

Step 8. Place screwdriver in slot “B”. (See Figure 4, page

14). Depress and turn counter-clockwise (

) to

stop. Control screw must be in “IN” position for

propane (L.P.) gas and in “OUT” position for natural

gas. STOP! Read label “For Your Safety” located on

your water heater.

Step 9. Set the thermostat to lowest setting by turning the

water temperature dial clockwise, (

) to its

lowest temperature setting (with arrow on dial) as

shown.

Step 10. Turn gas control knob clockwise

to “OFF”

position. Knob cannot be turned from “PILOT” to

“OFF” unless knob is depressed slightly. DO NOT

FORCE.

Step 11. Wait five (5) minutes to clear out any gas. If you

then smell gas, STOP! Follow “B” in the safety in-

formation on “For Your Safety” label. If you don’t

smell gas, go to the next step.

Step 12. Find pilot-follow metal tube from gas control. The

pilot is located in front of the burner. (See Figure 7,

page 14)

Step 13. If you don’t smell gas, turn knob on gas control

counter-clockwise to

“PILOT”

position.

Step 14. Push in control knob all the way and hold down.

Immediately light the pilot with a match. Continue

to hold control knob in for about one (1) minute

after the pilot is lit. Release knob and it will pop

back up. Pilot should remain lit. If it goes out, re-

peat steps 9 through 12.

If knob does not pop up when released, stop

and immediately call the local gas supplier.

If the pilot will not stay lit after several tries,

depress and turn the gas control knob clock-

wise

to “OFF” and call the gas supplier.

Step 15. Check for gas leaks with only pilot flame burning

using a soapy water solution, not a match or open

flame. Check for gas leaks at fittings “F”and “G”

(See Figure 7, page 14) and at fitting “J” (See Figure

5, page 14).

Step 16. Make sure temperature adjustment dial is turned

clockwise (

) in its lowest position (See

Figure 4, page 14).

Step 17. Replace inner and outer doors.
Step 18. At arms length away turn gas control knob to the

full “ON” position. WARNING: Do not use gas

control knob to regulate gas flow. Turn tempera-

ture adjustment dial counter-clockwise (

)

until gas flows to main burner and ignites.

Step 19. With a soapy water solution, not a match or open

flame, check for gas leaks at gas connection “H”.

(See Figure 5, page 14). If gas leak occurs, turn off

immediately by shutting off gas cock at inlet to

control,or by turning gas control knob to
“PILOT” pushing down and turning to “OFF”. Re-

pair gas leak as necessary, and repeat steps 9

through 19.

Step 20. At arm’s length away, set the thermostat to desired

setting. The mark (

▼) HOT indicative of approx.

120°F is preferred starting point. Some local laws

may require a lower starting point. If hotter water

is desired see the Temperature Regulation” sec-

tion in this manual.